KFD2GUTEX1D Temperature Converter With Trip Relays
|
|
List Price (ex VAT): |
£56.87 |
|
|
|
In stock |
|
|
Order Code: |
KFD2GUTEX1D |
|
|
Manufacturer Code: |
VOLTAGECURRENTTRIPAMPL |
|
|
|
|
|
Out Of Stock? You Can Still Place Your Order. |
|
| |
| |
| | | | |
|
|
Documentation:
K-System barriers
Datasheet
|
Product details
Intrinsic safety & signal conditioning
Temperature converter with trip point relays - 20mm
This isolated barrier is used for intrinsic safety applications. The device converts the signal of a resistance thermometer, thermocouple, potentiometer, or voltage source to a proportional output current. It also provides a relay trip value.
The removable terminal block K-CJC-** is available as an accessory for internal cold junction compensation of thermocouples.
A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output.
The device is easily configured by the use of the PACTware configuration software.
Technical specification
| Supply voltage: | 20-30V d.c.
| Power loss: | ≤2W
| Power consumption: | 2.2W
| Input/Output: | Analogue input
| No. of Channels: | 1
| Output:
Output I, II: | Relay
| Output III: | Analogue current output
| Current range: | 0-20mA or 4-20mA
| Open loop voltage: | ≤24V d.c.
| Load: | ≤650Ω
| Fault signal: | Downscale I ≤3.6mA
| | Upscale 1 ≥ 21mA
| Input: |
| RTD: | Pt100, Pt500, Pt1000, Ni100, Ni1000
| Types of measuring: | 2-, 3-, 4-wire technology
| Measuring circuit monitoring: | Sensor burnout, sensor short-circuit
| Thermocouples: | Type B, E, J, K, L, N, R, S, T
| Cold junction compensation: | External and internal
| Measuring circuit monitoring: | Sensor burnout
| Voltage: | 0-10V, 2-10V, 0-1V, -100-100mV
| Potentiometer: | 0.8-20kΩ
| Types of measuring: | 2-, 3-, 5-wire technology
| Input resistance: | ≥250kΩ (0-10V)
| | ≥1MΩ (0-1V, -100-100mV)
| Measuring current: | Approx. 400μA with resistance measuring sensor
| Ambient temperature: | -20 to +60°C
| Protection rating: | IP20
| Mounting: | 35mm DIN rail or panel mount
| Dimensions: | w40 x h119 x d115mm | |
Features:
3 port galvanic isolation
Single-channel isolated barrier
24V d.c. supply (power rail)
Thermocouple, RTD, potentiometer or voltage input
Redundant TC input
Current output 0/4mA to 20mA
2 relay contact outputs
Configurable by PACTware or keypad
Line fault (LFD) and sensor burnout detection
Up to SIL2 acc. to IEC 61508/IEC 61511
DIN rail/power rail solutions
Removable terminals reduce maintenance time
Fault detection and local indication
|
|
|
Other Customers Also Ordered These Items
|
|
|
|
|